Switching Power Supply
Product name : Switching Power Supply
Item : Triple output T-50W
Details :
Product Description:
Model /Specification
|
T-50A
|
T-50B
|
T-50C
|
T-50D
|
CH1
|
CH2
|
CH3
|
CH1
|
CH2
|
CH3
|
CH1
|
CH2
|
CH3
|
CH1
|
CH2
|
CH3
|
DC output voltage
|
5V
|
12V
|
-5V
|
5V
|
12V
|
-12V
|
5V
|
15V
|
-15V
|
5V
|
15V
|
24V
|
Output voltage error (Note2)
|
±2%
|
±5%
|
±5%
|
±2%
|
±5%
|
±5%
|
±2%
|
±5%
|
±5%
|
±2%
|
±6%
|
±6%
|
Rated output current
|
7A
|
1A
|
1A
|
5A
|
1A
|
1A
|
4A
|
1A
|
1A
|
3A
|
1A
|
1A
|
Output current rage
|
0.6-7A
|
0.2-1A
|
0.2-1A
|
0.6-5A
|
0.2-1A
|
0.2-1A
|
0.6-4A
|
0.2-1A
|
0.2-1A
|
0.6-4A
|
0.2-2A
|
0.2-1A
|
Wave and noise(Note3)
|
100mV
|
100mV
|
100mV
|
100mV
|
100mV
|
100mV
|
100mV
|
100mV
|
100mV
|
50mV
|
120mV
|
120mV
|
Inlet stability(Note4)
|
±0.5%
|
±0.5%
|
±0.5
|
±0.5%
|
±0.5%
|
±0.5
|
±0.5%
|
±0.5%
|
±0.5
|
±0.5%
|
±1%
|
±1%
|
Load stability(Note5)
|
±1%
|
±4%
|
±4%
|
±1%
|
±4%
|
±4%
|
±1%
|
±4%
|
±4%
|
±1%
|
±5
|
±5%
|
DC output power
|
52W
|
49W
|
50W
|
51W
|
Efficiency
|
66%
|
69%
|
71%
|
72%
|
Adjustable range for DC voltage
|
CH1+10,-5%
|
CH1+10,-5%
|
CH1+10,-5%
|
CH1+10,-5%
|
AC input voltage range
|
85~132VAC/170~264VAC selected by switch 47~63Hz;240~370VDC
|
Input current
|
1.6A/115V 0.8A/230V
|
AC impulse current
|
Cold-start current 20A/115V 40A/230V
|
Leakage current
|
<0.5A/240VAC
|
Overload protection
|
105%~150% Type:PULSING HICCUP SHUTDOWN Reset auto recovery
|
Over-voltage protection
|
……
|
High-temperature protection
|
Temperature coefficient
|
±0.03%℃(0~50℃) ON+5V OUTPUT
|
Setup rise hold up time
|
200ms,50ms,16ms
|
Vibration
|
10~500Hz,2G 3AXES 10min./1cycle,Period for 60min,Each axes
|
Withstand voltage
|
Input and output interval:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC
|
Isolation resistance
|
Input and output interval,Input and enclosure,Output and enclosure:500VAC/100M Ohms
|
Working temperature and humidity
|
-10℃~+60℃,20%~90%RH
|
Store temperature and humidity
|
-20℃~+85℃,10%~95%RH
|
Overall dimension
|
159*97*38mm
|
Weight
|
0.54Kgs
|
Safety standards
|
Meet UL1012 requirement(Not apply for the mark)
|
EMC standards
|
……
|
Note:
1.The testing condition for the parameter above is:230VAC input, rated load,25℃ 70%Rh,Humidity
2.Error,include the setting error, line stability and load stability.(Note:5)
3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5.Load stability test: The load is from 0% to 100%,others 60%.
6.C2、3、11must be knocked down.
|