Switching Power Supply

Product name : Switching Power Supply

Item : Triple output T-50W

Details :
Product Description:
Model /Specification
T-50A
T-50B
T-50C
T-50D
CH1
CH2
CH3
CH1
CH2
CH3
CH1
CH2
CH3
CH1
CH2
CH3
DC output voltage
5V
12V
-5V
5V
12V
-12V
5V
15V
-15V
5V
15V
24V
Output voltage error (Note2)
±2%
±5%
±5%
±2%
±5%
±5%
±2%
±5%
±5%
±2%
±6%
±6%
Rated output current
7A
1A
1A
5A
1A
1A
4A
1A
1A
3A
1A
1A
Output current rage
0.6-7A
0.2-1A
0.2-1A
0.6-5A
0.2-1A
0.2-1A
0.6-4A
0.2-1A
0.2-1A
0.6-4A
0.2-2A
0.2-1A
Wave and noise(Note3)
100mV
100mV
100mV
100mV
100mV
100mV
100mV
100mV
100mV
50mV
120mV
120mV
Inlet stability(Note4)
±0.5%
±0.5%
±0.5
±0.5%
±0.5%
±0.5
±0.5%
±0.5%
±0.5
±0.5%
±1%
±1%
Load stability(Note5)
±1%
±4%
±4%
±1%
±4%
±4%
±1%
±4%
±4%
±1%
±5
±5%
DC output power
52W
49W
50W
51W
Efficiency
66%
69%
71%
72%
Adjustable range for DC voltage
CH1+10,-5%
CH1+10,-5%
CH1+10,-5%
CH1+10,-5%
AC input voltage range
85~132VAC/170~264VAC selected by switch 47~63Hz;240~370VDC
Input current
1.6A/115V 0.8A/230V
AC impulse current
Cold-start current 20A/115V 40A/230V
Leakage current
<0.5A/240VAC
Overload protection
105%~150% Type:PULSING HICCUP SHUTDOWN Reset auto recovery
Over-voltage protection
……
High-temperature protection
Temperature coefficient
±0.03%℃(0~50℃) ON+5V OUTPUT
Setup rise hold up time
200ms,50ms,16ms
Vibration
10~500Hz,2G 3AXES 10min./1cycle,Period for 60min,Each axes
Withstand voltage
Input and output interval:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC
Isolation resistance
Input and output interval,Input and enclosure,Output and enclosure:500VAC/100M Ohms
Working temperature and humidity
-10℃~+60℃,20%~90%RH
Store temperature and humidity
-20℃~+85℃,10%~95%RH
Overall dimension
159*97*38mm
Weight
0.54Kgs
Safety standards
Meet UL1012 requirement(Not apply for the mark)
EMC standards
……
Note:
1.The testing condition for the parameter above is:230VAC input, rated load,25℃ 70%Rh,Humidity
2.Error,include the setting error, line stability and load stability.(Note:5)
3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5.Load stability test: The load is from 0% to 100%,others 60%.
6.C2、3、11must be knocked down.